New Arrivals/Restock

47-102684-204 Upgraded Heat Pump Control Board, Defrost Control Circuit Board Replace for Rheem 47-102684-14, 47-102684-07

flash sale iconLimited Time Sale
Until the end
23
57
11

$35.99 cheaper than the new price!!

Free shipping for purchases over $99 ( Details )
Free cash-on-delivery fees for purchases over $99
Please note that the sales price and tax displayed may differ between online and in-store. Also, the product may be out of stock in-store.
New  $59.99
quantity

Product details

Management number 210111021 Release Date 2026/04/02 List Price $24.00 Model Number 210111021
Category

The 47-102684-204 is a microprocessor-based demand defrost controller intended for heat pump systems. This controller uses basic differential temperature means to detect degradation of system performance due to ice build-up on the outdoor coil. The controller uses “self-calibrating” principles to calibrate itself to the heat pump system.

  • The47-102684-204 is a microprocessor-based demand defrost controller intended for heat pump systems. This controller uses basic differential temperature means to detect degradation of system performance due to ice build-up on the outdoor coil. The controller uses “self-calibrating” principles to calibrate itself to the heat pump system.
  • Rated Voltage : 24 VAC, Rated Voltage Range :18-30 VAC. Max. Power Consumption @ 24 VAC . 4.08 VA, Nominal Frequency . 50/60 Hz. Relay Load Ratings: Compressor Contactor Relay . 0 VA in rush, 6 VA holding. Fan Relay . 1/2 HP @ 240, 1/4 HP@ 120 VAC. Reversing Valve Relay (RV) . 24 VA. Auxiliary Heat Relay (D) . 1 Amp. 0.6 P.F. Operating Temperature Range . -40o to 150o F (-40o to 65o C).Humidity Range . 5% to 95% relative humidity(non-condensing).High Pressure Cutout Switch (HPC) :18 VAC, Low Pressure Cutout Switch (LPC) : 18 VAC.
  • Before removing the old controller, note the location of the OCT sensor on the outdoor coil. The new sensor should be attached to the coil in the same location, or as close as possible. The OAT sensor is typically 24-48” long, although some controllers have the sensor on the board. Placement of the OAT sensor is not as critical as the OCT sensor, but both sensors are required for the controller to operate.
  • Superior Quality, advanced microprocessor-based high-precision PCB manufacturing, soldering and assembly technology, professional tests to ensure optimal performance and long-lasting reliability.
  • Note: to save yourself some hassle, please take a picture of the old one before removing it, make sure getting the wires on the correct terminals.Please feel free to contact us if you have any questions about our products, your satisfaction would be our greatest motivation.
Item Weight 10.4 ounces
Part Number 16-02
Manufacturer kleeklea
Item model number 47-102684-204
Batteries Required No
Product Dimensions 5.48 x 3.5 x 2 inches
Included Components furance control board
Warranty Description 6 month

Correction of product information

If you notice any omissions or errors in the product information on this page, please use the correction request form below.

Correction Request Form

Product Review