Limited Time Sale$556.39 cheaper than the new price!!
| Management number | 212611079 | Release Date | 2026/04/06 | List Price | $370.93 | Model Number | 212611079 | ||
|---|---|---|---|---|---|---|---|---|---|
| Category | |||||||||
Electronic Engine ControlProduct DescriptionDC power supply + AC power supply + current detection + RS485 + USB + EHTERNETWorking power range: DC(8-35)V/AC(90~305)VDimensions (mm): 198*154*54Installation size (mm): 186*141Working temperature: (-25~+70)Weight: 0.8kgHAT600R series dual power supply automatic switching controller is an intelligent dual power supply switching module with programmable functions, automatic measurement, display and digital communication. It integrates digitalization, intelligence, and networking, and realizes automation in the measurement and control process, reducing human error. It is an ideal product for dual power switching.HAT600R series dual power supply automatic switching controller is composed of a microprocessor as the core, which can accurately detect two-way three-phase voltage, and make a response to abnormal voltage (over-voltage, under-voltage, phase loss, over-frequency, under-frequency) Accurate and fast judgment and output of passive control switch. The device is suitable for the power supply system of mains and mains, mains and power generation, power generation and power generation, and also fully considers the application in various ATS (automatic load transfer system), which can be directly used in PC level, CB level, The CC-level transfer switch can realize parallel switching or same-phase switching of two power sources at the same time. With its compact structure, advanced circuit, simple wiring and high reliability, it can be widely used in electrical installations, automatic control and debugging systems in industries and departments such as electric power, post and telecommunications, petroleum, coal, metallurgy, railway, municipal administration, and intelligent buildings.FeaturesWith fast switching function, the response time of automatic switching is as low as 50ms, and with the fast ATS switch, the switching time of less than 100ms can be realized;The same phase switching function can be realized;It can realize parallel switching function (only for HAT600RS), and display the voltage difference, frequency difference and phase difference of the two power supplies; is 132x64 pixels, with backlight, multi-language (simplified Chinese, English, others) display, touch button operation;LED lights can visually display the current ATS closing and opening status, power status and whether the load has power;The system type can be set as S1 mains S2 mains, S1 mains S2 power generation, S1 power generation S2 mains power, S1 power generation S2 power generation;S1 main use and S2 main use can be set, with automatic switching and automatic reset, automatic switching and no automatic reset switching mode for the main power supply;Collect and display two-way three-phase voltage, frequency and phase sequence status;Collect and display load active power, reactive power, apparent power, power factor and current;With S1/S2 independent over-current warning or tripping alarm function;With non-important load NEL tripping function;With load voltage monitoring function;With S1/S2 accumulated active energy, accumulated reactive energy, and accumulated closing times display;It can measure the waveform distortion rate of S1, S2 phase voltage and load current and the percentage of 3-21 odd harmonic components;It has the display of the current continuous power supply time and the cumulative power supply time of S1/S2;For energy storage switches, wait for the switch PF (ready to close) signal to be valid before closing;With overvoltage, undervoltage, overfrequency, underfrequency, phase loss and reverse phase sequence monitoring functions;Equipped with automatic/manual state switching, in manual mode, the switch can be forced to close and open;All parameters can be programmed on site, and password verification is adopted to prevent misoperation by non-professionals;It has the function of customizing the boot interface;The machine can be manually tested on site to start and stop the generator set;It has the function of switch reclosing and power off and then buckling;Closing output can be set as pulse or continuous output;Applicable to PC-level two-stage, PC-level three-stage, CB-level and CC-level switches;Two-way N line separation design;Real-time clock display, with history record function, can record 200 pieces of data in a loop;With black box function, it can record 5 groups of events when ATS automatically switches, and each group of events records 60 pieces of detailed data 50 seconds before the event occurs and 10 seconds after the event occurs;It has the function of start/time non-start of the generator set, which can be set for single operation, monthly or weekly operation, and can be set whether to run with load;It can control two generator sets to realize cycle operation, main operation and balanced time operation;The DC power supply range is extremely wide, and can withstand up to 80V DC input instantane
| Model | JZRYQJGJ |
|---|---|
| Brand Name | JZRYQJGJ |
| Part Number | JZRYQJGJ |
| Contact Type | Normally Closed |
| Manufacturer | JZRYQJGJ |
| Mounting Type | Chassis Mount |
| Connector Type | Clamp |
| Current Rating | 0.01 Amps |
| Contact Material | Aluminum |
| Specification Met | UL |
| Contact Current Rating | 1 Amps |
If you notice any omissions or errors in the product information on this page, please use the correction request form below.
Correction Request Form